Glycol Buffer Bottle
- Use a thermal buffer with your probe to
prevent nuisance alarms.
Glycol, Glass Beads, IceClear PGX. Specify buffer solution on order.
Request Quote
Glycol, Glass Beads, IceClear PGX. Specify buffer solution on order.
Request Quote
Stainless Temperature Probe with Platinum RTD sensor
Datalogging thermometer that meets 21 CFR 11 requirements, are ideal for monitoring temperatures in refrigerators, freezers, water baths, heating blocks, and incubators. High-accuracy thermometer has a temperature range of -50 to 70°C and resolution of 0.01°C and maintains an accuracy of ±0.25°C across the entire temperature range.
Uses your existing WiFi network to monitor across all your facilities. Automates monitoring of temperature, humidity, differential pressure, CO2 and more to meet compliance standards with 24/7 real-time continuous monitoring. Alerting system uses emails, text messages and APPs for notifications. The system meets 21 CFR 11 requirements, are ideal for monitoring of refrigerators, freezers and ultralow freezers.
[maxbutton id="1" url="https://www.aegisfridge.com/contact/" ]Sentinel Next RTD probe with Dry Contact for ultra-low freezers and liquid nitrogen chambers. Used in tissue and blood storage, pharmaceutical and other healthcare applications
Probe Length & Diameter Stainless probe: 25mm, Ø 4mm (1”, Ø 0.16”)
Cable Length: 183cm (6ft)
Measurement Range: -200°C to +150°C (-328°F to +302°F)
Accuracy: ±0.2°C (±0.4°F) at 25°C (77°F)
Response Time: (to reach 90%) In water, with stirring: <10sec
Display Resolution: 0.1°C (0.1°F)
Optional DI (Digital Input): dry contact available
Door Contact
Circuit type Open loop
Operation gap ½”(13mm)
Color: White
Terminals: Screw-type
Mounting Tabs: Yes
Case: High-impact ABS plastic
Contacts: Deactivated rhodium on gold under-plating
Contact rating: 0.1A@100VDC (max) 1.0A@10VDC (max) 10W (max)
Temperature: -15°~160°F (-25°~70°C)
Switch cycles: 50 Million (0.1mA@5VDC)
Switch Dimensions: 21/2′′x9/16′′x1/2′′ (63.5x14x13mm)
Magnet Dimensions: 21/2′′x1/2′′x1/2′′ (63.5x13x13mm)
Magnet Type: Ferrite
Probe Dimensions: 7.6cm x 9.5cm x 3.8cm (3” x 3.75” x 1.5”)
Cable Length: 100cm (~39”)
Operating Principle: Non-dispersive infrared (NDIR)
Measurement range: CO2 0 to 30%vol(CO2)
Measurement RH: 0 to 100% (non-condensing)
Measurement range: -40 to 60 °C
Accuracy: ± 0,25vol ± 3% of reading
Operation temperature range: 0 to 50 °C
Operation humidity range: 0 to 95% RH (non-condensing)
Display Resolution: 0.1°C (0.1°F)
[maxbutton id="1" ]
Sentinel Next Temperature and Relative Humidity Connector
Temperature Measurement Range: -40°C to +125°C (-40°F to +257°F)
Accuracy: ±0.3°C (±0.5°F)
Relative Humidity Range: 0 to +100% RH
Response Time: (to reach 66%) 5 to 30sec for T; 8sec for RH
Display Resolution: 0.1°C (0.1°F)
The countertop blanket warmers for labor and delivery rooms, ICU and NICU
• Glass window to view contents inside
• Energy-efficient coated glass door
• Standard lights, UV lamps, with circulation fan
• Digital temperature limiter
Aegis provides affordable, low power Wi-Fi sensor network solutions that make a ubiquitous sensing world come alive and a full line of controlled temperature cabinets. Laboratory, Pharmacy and Chromatography refrigerators and freezers which are designed to meet the dimensional and temperature requirements of the scientific community.
OH: 513 204 5837
PA: 215-281-9180